Material Decontamination

Decontamination Chamber MD-C

PBSC’s high-level Log6 surface disinfection chamber is a modular design, ideal for material production environments and equipment loads.

Material Decontamination

Decontamination Chamber MD-C

PBSC’s high-level Log6 surface disinfection chamber is a modular design, ideal for material production environments and equipment loads.

Overview

PBSC’s high-level log6 surface disinfection chamber is a freestanding, modular unit ideal for material production and equipment loads in cleanroom and high containment environments up to BSL4. At PBSC we provide decontamination solutions from market-leading H202 generator manufacturers ensuring regulatory compliance and consumable traceability. The chamber is intuitive allowing ease of use for facility operators.

The decontamination cycle is initiated via the colour touch screens on either side of the chamber, which provides operators with in-cycle data from the chamber and H2O2 generator.

Effective against a wide range of micro-organisms and viruses, the HPV decon chamber provides a low heat decontamination solution for heat-sensitive items such as laptops, or biologic preparations. The decontamination chamber is a crucial addition to a facility’s process philosophy for material transfer either into or out of the critical environment.

The chamber includes either an S7-1200 or S7-1500 PLC with Ethernet data communication.

Various chamber sizes with pneumatic seal doors are available, from 1m x 1m up to 3m x 5m (WxD)

Features

  • Flush Maglock
  • Colour Touch Screen
  • Override Buttons
  • Stainless-Steel Hinges with concealed air supply
  • Tacho Monitored Fans
  • Large Vision Panel Double Glazed
  • Robust Bumpers
  • Plug and play electrical spares for ease of maintenance
  • Option for air handling system without connection to the building HVAC
  • Flush threshold allowing easy wheeled access
  • Range of aeration and air handling options to suit customers’ requirements
  • Full service support contracts available to suit GMP and Life Science facilities

Technical Specification

  • Fast Cycles from 45 minutes
  • Log6 decontamination
  • Siemens S1200 or S1500 PLC, with either 7”, 12” or 15” Comfort Touch Screens
  • Data acquisition and management to allow for 21 CFR Part 11 and Annex 11 compliance
  • Internal power sockets, to allow electrical items to be run during the fumigation cycle
  • Turnkey solution including all validation
  • PBSC reserve the right to introduce changes in performance, configuration and technology, dimension, weights and materials in the course of technical progress. Images may not be accurate.
  • Some of the information/images/equipment described or shown may only be available at extra cost. Features & specifications will vary.
  • Please contact PBSC for specific design options.

Options

  • Project Specific Approval Drawing
  • DQ package including FDS, P&ID, HDS etc
  • Installation services
  • Commissioning of Chamber
  • IQ-OQ
  • Operator Training
  • Gas Cycle Development
  • Performance Qualification
  • 6-12 months-servicing/calibration
  • Range of aeration and air handling options

DATASHEET

How Can We Help?

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Need Some Help?

Visit Us

Auckland, New Zealand

Melbourne, Australia

  • 1800 754 617
  • Unit 8, 2-20 The Gateway, Broadmeadows, VIC 3047, Australia